AC Leaking Water Inside the House? Causes and How to Fix It
Your AC pulls a lot of water out of Miami air: on a humid summer day a typical home system can remove several gallons. That water is supposed to run off the indoor coil, into a drain pan and out through a drain line. When it ends up on your floor, ceiling or in the closet, something in that path has failed.
Do this first
- Turn the AC off at the thermostat so it stops making more water.
- Check the float switch. Many systems have a safety switch in the drain pan or line that shuts the AC off when water backs up. If your AC stopped cooling and there is water, that switch has probably done its job.
- Mop up and move anything valuable away from the air handler. In a condo, check whether water is reaching the unit below.
The common causes
1. A clogged condensate drain line
By far the most common cause in South Florida. Algae and slime grow in the warm, wet drain line until water can no longer get out, so it overflows the pan. You may also notice a musty smell.
Tip: if you can find the drain line’s cleanout (often a short pipe with a cap near the air handler), pouring a cup of white vinegar into it every few months helps keep algae down. It will not clear a line that is already blocked.
2. A rusted or cracked drain pan
Older systems often have metal pans that rust through. Water then drips straight through the bottom instead of going to the drain. This is common in condo closets where the air handler sits above the water heater.
3. A frozen evaporator coil
If the coil freezes, the ice melts when the system cycles off, and more water arrives at once than the pan can handle. Causes are a dirty filter, a blocked return, a failing blower or low refrigerant. If you see ice on the copper lines or frost on the coil, turn the AC off and let it thaw.
4. A failed condensate pump
Units that can’t drain by gravity use a small pump. When the pump fails, water backs up fast.
5. Water from a vent or the ceiling
Water dripping from a supply vent is usually condensation: cold air meeting humid air around the duct or the vent boot, often because of torn insulation or a leaky duct in the attic.
When it is more than a drain problem
A drain that clogs once is maintenance. A system that keeps freezing, keeps overflowing or leaks from the ceiling usually has an underlying cause: airflow, refrigerant charge, or duct problems. We measure temperatures and pressures to find it, so the leak doesn’t come back next month.
Mold and a musty smell often come with water problems. If that is what you are noticing, read mold in AC vents. Living in a condo? See condo AC repair; drain problems there can affect your neighbours too.